Solvent Delivery Pump

9160---Copy

YL9112 Isocratic Pump

  • No mixing valve
  • Operating principle : Parallel dual-plunger pump
  • Easily upgraded to YL9110 Quaternary pump

YL9110 Quaternary Pump

  • Operating principle :Parallel dual-plunger pump,Low-pressure gradient
  • Number of Solvent :up to 4 solvents
  • Gradient formation : 4-channel mixing valve
  • Composition Precision : < 0.1 %
  • Composition Accuracy : < 0.5 %

YL9111 Binary Pump

  • Operating principle : Double Parallel dual-plungerpump, High-pressure gradient
  • Number of Solvents : 2

Detector

9160---Copy

YL9120 UV/Vis Detector

  • Wavelength Range : 190-900 nm
  • Data collection rate : up to 50Hz
  • Light Source : Deuterium lamp & tungsten lamp
  • Noise level : <±0.5 X 10-5 AU , 254 nm, dry cell
  • Drift : <1 X 10-4 AU/hr
  • Bandwidth : 5.5 nm
  • Wavelength Accuracy : ±1 nm
  • Wavelength Precision : ±0.1 nm
  • Linearity : >99.5 % for 2.5 AU (acetone, 254 nm)
  • Path Length : 10 mm ( Analytical cell ) / 3 mm ( Semi-prep cell )
  • Cell Volume : 10 μL ( Analytical cell ) / 5 μL ( Semi-prep cell )

YL9160 PDA Detector

  • Slit Bandwidth : 1.7 nm
  • No. of PDA Channel : 1024
  • Pixel Resolution : 0.9 nm
  • Wavelength : 190~950 nm
  • Analytical Cell- Path-length : 10 mm- Pressure : < 1500 psi- Volume : 13 μL
  • Semi-prep cell- Path-length : 3 mm- Pressure : < 1500 psi- Volume : 5 μL
  • Noise Level : < ± 2 x 10-5 AU (Empty Cell, 1 sec Rise Time, 254 nm)
  • Drift : < 2 x 10-4 AU/hr (Baseline Correction), 0.001AU/hr (Room Temp)
  • Wavelength Accuracy : < 1 nm (HY-1 Holmium Oxide Filter)
  • GLP Compliance:
    • Photometric Accuracy, Linearity, Noise Level, Drift
    • System Check

YL9170 Refractive Index Detector

  • RI Range : 1.00 ~ 1.75 RIU
  • Noise : ≦ 5 x 10-9 RIU (Analytical) / ≦ 10 x 10-8 RIU (Semi-prep)
  • Flow Cell Volume : 9 μL (Analytical) / 7 μL (Semi-prep)
  • Cell pressure : 6 kg/cm2 (84 psi)
  • RS232 Control

Vacuum Degasser

YL9100 system2 - Copy

YL9101 Vacuum Degasser

  • Number of channel : 4 Channels
  • Maximum flow rate : 10 mL/min per channel> 0 ~ 2.0 mL/min per channel for 70 % Gas Removed from Methanol
  • Internal volume per channel : 925 μL per channel
  • Materials in contact with solvent: TeflonAF and PEEK

Column Compartment

`

YL9131 Column Compartment

  • Temperature range : 4 °C (Cooling) – 90 °C
  • Temperature stability : ±0.05 °C
  • Temperature accuracy : ±0.5 °C
  • Temperature programs : 40 Steps
  • Column capacity :
    • Analytical : Max. 3 ea of 30 cm column(Max. OD 18 mm)
    • Semi-prep : Max. 2 ea of 30 cm column
  • Heat-up time : 16 minutes from 4 °C to 90 °C
  • Cool-down time : 13 minutes from 90 °C to 4 °C
  • Column switching : max. two automatic 6-port valve (optional)

Autosampler

Alias

YL9150 Autosampler (Alias)

The YL9150 is a high-throughput autosampler with state of the art injection technology, fast injection and wash cycles, and an optional Peltier chiller/heater for samples. Full or partial loop injection along with Pressure-Assisted-Sample-Aspiration (PASATM ) is possible.

The highly efficient needle and internal capillary wash virtually eliminates sample carry-over. Cycle time, including wash, is less than one minute.

96 standard 2 mL vials (32 mm x 12 mm) or well plates (96 or 384 capacity, deep or shallow) can be used.

  • Sample capacity :
    • Analytical : 2 Micro Well Plates according to SBS standards
    • Semi-prep : 24 vials of 10 mL (LSV)
  • Loop volume : 1 – 9999 μL programmable
  • Reproducibility :
    • RSD ≦ 0.3 % for full loop injections
    • RSD ≦ 0.5 % for partial loopfill injections
    • RSD ≦ 1.0 % for μL pickup injections
  • Carry-over : < 0.05 %
  • RS232 Control
  • Cooling/Heating option : 4 °C ~ 40 °C
YL9151_R

YL9151 Autosampler (OPTIMAS)

The YL9151 provides the optimum balance of economics and performance, optimising your injection automation, with a carousel holder for sample vial flexibility.

With its three injection modes including zero sample loss injection, YL9151 rivals top class autosampler performance, while challenging middle-class autosampler prices.

  • Capacity : 84 standards 2 mL vials
  • Control : Keypad / Software control by RS-232

Manual Injector

rheodyne-vent

Rheodyne 7725i / 9725i

  • Industry standard manual injector
  • Analytical : 7725i(SUS) and 9725i(PEEK)
  • Semi-prep : 3725i

Column Swiching Valve

MX Series II™ (Stand-alone)

MX Series II™ automated high-pressure fluidic valves provides productivity enhancing solutions for today’s demanding analytical methods. Combine MX Series II modular valves with your current instrument to support complex fluid switching and sample injection needs.

TitanHP™

TitanHP™ consists of an integrated driver/actuator and a removable liquid-end (Rapid Replacement Pod™) to provide a single, flexible space saving design. Eliminating the need for development of an internal board and firmware means shorter product development cycles and reduced time-to-market.

DuraLife® wear surfaces extends valve lifetime, which means reduced field service and more customer analysis time between replacements of the wetted surfaces.

YL9300 HPLC

(High Performance Liquid Chromatograph)

Vacuum Degasser

  • Number of channel: 4 CHs
  • Maximum flow rate: 10 ml/min per channel
  • Internal volume per channel: 925 ul per channel
  • Solvent contact materials: Teflon AF, PEEK and Glass-filled PTFE
Screen Shot 2014-12-04 at 3.26.15 PM

Quaternary Pump

  • Flow range:
    • 0.001-5 ml/min (Standard)
    • 0.001-10 ml/min (Option)
  • Flow rate accuracy: ≦ ±1% at 1 ml/min
  • Flow rate precision: < 0.1% RSD at 1 ml/min
  • Number of eluent lines: 4
  • Pressure pulsation: ≦ ±0.5 % at 1 ml/min

UV/VIS Detector

  • Wavelength range: 190~600 nm (Standard) /190~900 nm (Option)
  • Spectral bandwidth: 5 nm
  • Wavelength accuracy: ±1 nm
  • Wavelength precision: ±0.1 nm
  • Linearity: > 99.5% at 2.5 AU (Acetone, 254 nm)
  • Noise level: < ±0.35 X 10-5 AU, 254 nm, dry cell
  • Drift: < 1 X 10-4 AU/hour

System Information

  • Data communications: LAN
  • Dimension: 375 X 470 X 545 mm (W X H X D)
  • Weight: 27 Kg
  • Safety & maintenance: Leak detection, Diagnostics, Error detection
  • Power consumption: 150 W

YL9330 Column Compartment

  • Temperature range : 4°C (Cooling) – 90 °C 
  • Temperature stability : ±0.05°C
  • Temperature accuracy : ±0.5°C, with 2-point temp. calibration
  • Temperature programs : 40 Steps
  • Column capacity :
    • three columns up to 300mm length
    • (max OD: up to 18mm)
  • Column switching (Option): automatically 6-port SS(PEEK) valve up to 2 ea 
  • Communications: LAN 
  • Safety & maintenance : Leak detection, Diagnostics, Error detection 
  • Dimensions : 185 x 476 x 480mm (W x H x D) 
  • Line Voltage : 100-240VAC, ±10%, automatic voltage selection 
  • Line frequency : 50/60Hz, ±5% 
  • Power consumption : 150W
young lin-bottom